What Is Laminated Glass and When Should It Be Used?
Laminated glass offers a unique combination of safety, security, and acoustic performance. Here's everything you need to know about how it works and where it should be specified.
Rez Glass Industries 2026-03-02
What Is Laminated Glass?
Laminated glass consists of two or more layers of glass bonded together with an interlayer — most commonly polyvinyl butyral (PVB) or Sentry Glass Plus (SGP). When the glass breaks, the interlayer holds the fragments in place, preventing the panel from collapsing and reducing injury risk.
How It's Made
The glass layers and interlayer are assembled in a clean room environment to prevent contamination. The assembly is then passed through heated rollers to remove air and create an initial bond, followed by an autoclave process using heat and pressure (typically 135°C and 12 bar) to achieve a permanent, optically clear laminate.
PVB vs. SGP Interlayers
PVB (Polyvinyl Butyral) is the most common interlayer, offering good optical clarity, sound dampening, and UV resistance. It is used in standard architectural, automotive, and residential applications.
SGP (SentryGlas Plus) is significantly stiffer and stronger than PVB — up to five times stronger — making it ideal for structural applications, hurricane-rated glazing, balustrades, and overhead glazing where post-breakage integrity is critical.
Key Benefits
- Safety: Broken fragments remain attached to the interlayer, reducing laceration risk.
- Security: Laminated glass resists forced entry far better than monolithic glass — the interlayer continues to hold even under repeated impacts.
- Sound control: The viscoelastic PVB interlayer dampens sound transmission, making it effective for acoustic glazing applications.
- UV protection: PVB blocks up to 99% of ultraviolet radiation, protecting interior furnishings and occupants.
- Overhead glazing safety: Building codes require laminated glass for skylights, overhead glazing, and sloped applications where falling glass poses a hazard.
When Should Laminated Glass Be Specified?
Laminated glass should be used when one or more of the following conditions apply:
- The glass is in an overhead or sloped location (skylight, canopy, sloped wall)
- Security glazing is required (storefronts, banks, schools)
- Acoustic performance is a priority (residential windows near roads, commercial offices)
- The application requires post-breakage retention (balustrades, glass floors, structural glazing)
- Hurricane or impact resistance is required
- Building code mandates safety glazing in a specific location
Laminated vs. Tempered: Which to Choose?
Both tempered and laminated glass are safety glazing products, but they behave differently on failure. Tempered glass shatters into small granular pieces; laminated glass holds together. For overhead, structural, or security applications, laminated is typically the better choice. For shower glass and interior partitions, tempered is standard.
Custom Configurations at Rez Glass
We fabricate custom laminated glass assemblies including 6mm + 6mm, 8mm + 8mm, tempered laminated, and SGP structural laminates. Lead times are 2–7 business days. Contact us for project specifications and pricing.